FTS125-CTV Data Sheet #:
SG185
Page 7
Rev:
02
Date:
01/03/12
Copyright 2012 The Connor-Winfield Corp. All Rights Reserved
Specifications subject to change without notice
Phase Noise:
OffsetFrequency(Hz))
CTV(dBc/Hz)
10
-70
100
-105
1k
-135
10k
-145
100k
-152
1M
-158
Phase Noise
Figure 3
Antenna Requirements
Table 7
Parameter
Notes
TheFTS125antennaconnectorisanMCX(female)
TheantennasupplyvoltageprovidedtoPin14mustbewithintherangeof2.7to13.2V(AMR);
theantennamustbeabletooperateatthisvoltage
Theantenna’scontinuouscurrentdrawmustbe<=45mA
Theantennamusthaveafullskyviewforoptimalreceiverperformance
Anactiveantennawithaminimum10dBgain(includingcableloss)shouldbeused
Standard 125 Series models are designed for fixed position operation only. Contact Connor-Winfield Sales for mobile application model offerings